  • Five measured gases: HC, CO, CO₂, O₂ and NO
  • NDIR sensing for HC, CO and CO₂
  • Electrochemical sensing for O₂ and NO
  • Automatic air–fuel ratio and lambda calculation
  • LCD display, RS-232C output and 200 measurement groups

Final configuration, specifications, accessories, packaging, and delivery terms are confirmed in the quotation.

PRODUCT DETAILS

Features, construction, and applications

Review the available product detail images for the selected equipment.

NHA-506EN gas analyzer above its five-gas range, power, dimensions and net-weight table
Confirmed brochure configuration: AC 220 V, 6 kg, 260 × 180 × 450 mm.
NHA-506EN measurement principles, T90 response times and warm-up
Confirmed brochure configuration; illustrative equipment image.
NHA-506EN dimensions, 6 kg net weight and AC power requirements
Confirmed brochure configuration; illustrative equipment image.
NHA-506EN 200 measurement groups, RS-232C and optional accessories
Confirmed brochure configuration; illustrative equipment image.

TECHNICAL DATA

Specifications

Values below follow the supplied product listing. Confirm the final selected configuration before ordering.

Product specifications

Measured gasesHC, CO, CO₂, O₂ and NO
HC measurement range0–9,999 ppm (n-Hexane)
CO measurement range0–10%
CO₂ measurement range0–18%
O₂ measurement range0–25%
NO measurement range0–5,000 ppm
HC accuracy, 0–2,000 ppm±12 ppm absolute or ±5% relative, whichever is larger
HC accuracy, 2,001–9,999 ppm±10% relative
CO accuracy±0.06% absolute or ±5% relative, whichever is larger
CO₂ accuracy±0.5% absolute or ±5% relative, whichever is larger
O₂ accuracy±0.1% absolute or ±5% relative, whichever is larger
T90 response timeHC / CO / CO₂: <10 s; O₂: <12 s; NO: <15 s
Warm-up time10 minutes at ambient temperature ≥20°C
Power supplyAC 220 V ±10%, 50 Hz ±1 Hz
Net weight6 kg
Dimensions (W × H × D)260 × 180 × 450 mm
Data storage200 measurement groups
Digital interfaceRS-232C

Installation requirements

Confirm AC 220 V ±10% at 50 Hz ±1 Hz, a suitable instrument support, sampling access and workshop ventilation. Allow the listed 10-minute warm-up at ≥20°C. Follow the supplied operating manual for sampling, leak checks, calibration, filters and condensate handling. Confirm power inverter and accessory configuration if vehicle-based power is needed.

Product overview

Five-gas analysis for gasoline-engine maintenance

The NHA-506EN Automotive Emission Analyzer measures HC, CO, CO₂, O₂ and NO in vehicle exhaust. It uses non-dispersive infrared (NDIR) analysis for HC, CO and CO₂, with electrochemical sensing for O₂ and NO. The brochure lists use with gasoline, CNG, LPG and ethanol-gasoline engine fuels. Confirm the vehicle and fuel configuration when requesting a quotation.

Read gas concentrations and mixture information

The LCD displays measurement information, with automatic calculation and display of the air–fuel ratio (A/F) and lambda air ratio. The five channels have different measurement ranges: HC 0–9,999 ppm (n-Hexane), CO 0–10%, CO₂ 0–18%, O₂ 0–25% and NO 0–5,000 ppm. Follow the operating and calibration instructions when interpreting readings.

Portable instrument with measurement records

The confirmed configuration weighs 6 kg and measures 260 mm wide × 180 mm high × 450 mm deep. It provides an RS-232C digital interface and storage and review of 200 measurement groups. Confirm software compatibility and the required data format before connecting it to an existing inspection system.

Electrical supply and preparation

The specified mains supply is AC 220 V ±10%, 50 Hz ±1 Hz. The listed warm-up time is 10 minutes when ambient temperature is at least 20°C. A DC 12 V vehicle power inverter is an accessory option; the instrument must not be treated as a direct DC 12 V input device.

Accessories and quotation scope

The brochure describes RPM measurement using an inductive pickup and oil-temperature measurement using a probe. Confirm which sensors and leads are included in the quoted package. A micro printer, alternative RPM adaptors and a DC 12 V vehicle power inverter are listed as options/accessories. Request the sampling probe, hose, filters, calibration instructions and consumable list for the offered configuration.

One-stop equipment supply for a new workshop

Send BAOHUA your complete workshop equipment and tool list together with your exhaust-analysis requirements. We can help coordinate equipment selection and consolidated shipping. Confirm the final package, packing data, destination and shipment arrangements in the quotation.

Common purchasing questions

**Does this model measure NO or NO₂?** The confirmed NHA-506EN brochure and operating manual specify NO. NO₂ measurement is not claimed for this configuration.

**Is the printer included?** The micro printer is listed as an option/accessory. Confirm it in the quotation rather than assuming it is included.

**Can it run from a vehicle battery?** The brochure lists a DC 12 V vehicle power inverter as an accessory option. The main instrument supply is AC 220 V; confirm the inverter and cable package before ordering.

Product imagery

The orange-yellow and dark-grey workshop image is an illustrative rendering based on the supplied product reference and requested finish. Confirm the ordered finish and included accessories in the quotation.

MODEL SELECTION

How to choose this equipment

Selection guidance

Do I need all five gas channels?
Choose this configuration when HC, CO, CO₂, O₂ and NO readings are required. Identify the fuel type and required measurement ranges before ordering.
What should I confirm for workshop power?
Provide AC 220 V ±10%, 50 Hz ±1 Hz. If using vehicle power, confirm the optional DC 12 V inverter; direct DC input is not specified.
Do I need RPM, oil temperature or printed records?
List the required pickup, temperature probe, printer and adaptor types in the quotation request. Confirm supplied items individually.
Can it connect to existing inspection software?
The instrument has an RS-232C interface. Send the software and communication requirements for compatibility confirmation.

Compared with related models

Compare the gas channels, ranges, required sampling accessories and data interface before choosing an exhaust analyzer. This NHA-506EN is a five-gas configuration that includes NO as well as HC, CO, CO₂ and O₂. It measures gas concentrations; do not treat these readings as a smoke-opacity result. The optional printer and power inverter should be compared as part of the quoted package. Approval for a particular statutory inspection programme requires separate documentation and is not established by this listing.

BUYER SEARCH GUIDE

Five-gas analyzer purchasing guide

For vehicle exhaust-gas measurement during automotive maintenance. Confirm fuel, sampling conditions and calibration requirements; statutory inspection approval requires separate documentation.

Common sourcing language

Importers, distributors, and workshop buyers may describe NHA-506EN 5-Gas Automotive Exhaust Analyzer using these related terms:

  • NHA-506EN five-gas analyzer
  • automotive emission analyzer
  • HC CO CO2 O2 NO analyzer
  • gasoline engine exhaust analyzer

What to compare before ordering

Compare the five gas channels, measurement ranges, AC 220 V supply, sampling accessories and RS-232C interface. Confirm RPM and oil-temperature probes, optional printer and vehicle power inverter in the quotation.

COMPARE THE RANGE

View Vehicle Testing & Diagnostics

Compare related models and choose the configuration that matches your vehicles, process, utilities, and workshop layout.

View category

PROJECT SUPPORT

Tell us the vehicles, floor space, and services you plan to offer.

We will help organize the equipment list and identify the questions that must be confirmed before quotation and installation.

Start a project brief